QCJ-2000 Digital Integrator

Release Date:

2021-06-22

QCJ-2000 Digital planimeter
Instruction Manual
 
Harbin Optical Instruments Factory Co., Ltd.
 
 
 

 

QCJ-2000 Digital Integrator

Instruction Manual

Product Implementation Standard: Q/HGY18-2020

I. Uses

The QCJ-2000 digital integrator can rapidly measure irregular shapes of any form and any scale.

Area is widely used in agriculture, forestry, geology, exploration, water conservancy, urban planning, land surveys, and other fields.

The theodolite is a commonly used instrument among engineering and technical personnel for conducting scientific research, guiding production, and measuring areas.

II. Main Technical Specifications:

Maximum measurement range—graphics up to 300 mm wide, with no limit on length

Relative error — ±0.2%

Display Mode — 16-bit Dot-Matrix LCD Display

Power Supply Voltage – Internal Storage Power Supply DC 6V

III. Features of the Instrument:

1. May be set at any ratio;

2. Units that may be specified; (hectares, square kilometers, square meters, square centimeters; acres, square miles,

Square feet, square inches; city qing, mu, fen, and square feet.)

3. There are 8 storage units (m 2 /1; ft 2 /2; fen/3; km 2 /4; mi 2 /5; mu/6; ha/7;

ac/8)

4. Multiple measurements of different areas can be summed;

5. The same area can be measured multiple times to calculate the average;

6. Area unit conversion is supported.

IV. Instrument Structure:

The QCJ-2000 digital integrator consists of a main unit and a power supply charger. The structure of the instrument’s main unit and

The names of the individual components are shown in Figure 1. The functions of the keys are shown in Figure 2.

V. Introduction to Function Keys and Display Status

1. The function buttons are shown in Figure 2.

2. Introduction to Function Buttons and Display Status

(1) unit: preset unit key.

This key is used in conjunction with the unit keys (as shown in Figure 2), as well as the Enter and Esc keys. The operating procedure is as follows:

Set the power switch to ON, the instrument displays measur

0.■cm 2 , press unit, instrument display

MODULE

centimeter 2 , press m 2 /1, the instrument displays MODULE

m 2 , press enter, at this moment the instrument's

The unit is set to square meters.

(2) scale: preset ratio key

This key and centimeter 2 /0, m 2 /1. ft 2 /2, fen/3, km 2 /4、mi 2 /5, mu /6, ha /7, ac /8, qin /9,

Use keys such as Enter and Esc in combination. The procedure is as follows:

Press Esc, the instrument displays "area"

0.0m 2 , press scale, the instrument displays SCALE

1: — ,

Press m 2 /1, cm 2 /0, the instrument displays SCALE

1:10, press Enter, and the instrument displays “area.”

0.0m 2

At this time, the instrument’s scale is set to 1:10.

(3) trace: trace control key.

This key controls whether the instrument is in measurement mode. After the instrument’s scale and units have been set, press trace,

Instrument display TRACE

0.0m 2 , the mobile tracer moves along the contour of the area under test and stops at the starting point.

Press Enter, the instrument displays S:

×.×m 2 , ×.× square meters is the measured area of the figure. (Note:

During measurement, the display does not show any data; it only displays when you press The result is displayed only after you press Enter to confirm.)

(4) Enter: Confirm key.

While conducting unit, scale, f 1 f 2 , f 4 , f 5 When performing control-key operations such as “trace,” you must use Enter.

Press the key to confirm the completion of an operation.

(5)esc: Exit key:

While conducting f 1 , f 2 , f 3 , f 4 When operating control keys such as scale and unit, the Esc key must be used to complete the operation.

Mutual switching of functions. Press this key, and the instrument displays area

0.0 cm 2

(6)f 5 : Storage key

The procedure for operating this key is as follows:

The mobile tracer measures a specific area under test; press. Enter, the instrument displays S:

×.×m 2 , press

f 5 , the instrument displays STOCK ■, press m 2 /1, the instrument displays STOCK

01■, press Enter, instrument

Device display TRACE

0.0m 2 , ×.× data information is stored in m 2 /1 Within the storage area, the instrument is now restored.

Original measurement state.

(7)f 4 : Display storage key

The operation procedure for this key is as follows:

Press Esc, the instrument displays "area"

0.0m 2 , press f 4 , the instrument displays SHOW ■, press m 2 /1,

Instrument display SHOW

01■, press Enter, and the instrument displays S:

X.Xm 2 , ×.× square meters is

m 2 /1 Data information in the storage unit.

(8)f 2 : Sum key.

The operation procedure for this key is as follows:

Measure multiple areas, store the measurement data in different storage zones, then press. Esc, instrument display

area

0.0m 2 , press f 2 , the instrument displays SUMMAT

Σ1-8■, press Enter, and the instrument displays

S:

×.×m 2 , ×.× square meters is the sum of multiple areas.

(9)f 1 : Average key.

The operation procedure for this key is as follows:

After measuring the area multiple times and storing the measurement data in different storage units, press Esc, instrument

Display area

0.0m 2 , press f 1 , the instrument displays AVERAGE

X ■, press Enter, and the instrument displays

S:

×.×m 2 ,×.× square meters is the average value of a certain area.

(10)f 3 : Clear memory key.

The operation procedure for this key is as follows:

Press Esc, the instrument displays "area"

0.0 cm 2 , press f 3 , the instrument displays STOCK 0.0, at this moment 8

All data in the storage area has been cleared.

(11) RESET: Reset button.

Press this key, and the instrument displays measure

0.■cm 2 , at this point it corresponds to the display state when the power switch is turned on.

Similarly, the instrument is in the initialization state, with the default input ratio set to 1:1, unit is cm 2 , memory is 0. At work

If this key is accidentally pressed during operation, the instrument will revert to the initialization state, and all relevant parameters must be reset before measurements can be taken.

Number.

(12) test: Test key.

This key is the factory-preconfigured precision calibration key for the instrument. If the user accidentally presses this key, the instrument will display TEST character

When, please use After resetting, proceed with other operations.

3. Conversion of Area Units

The procedure is as follows:

After the instrument completes a measurement, press Enter, the instrument displays S:

×.× cm 2 , press f 5 , the instrument displays

STOCK

■, press ft 2 /2, the instrument displays STOCK

02■, press Enter, and the instrument displays

TRACE

0.0 cm 2 , press Esc, the instrument displays "area"

0.0 cm 2 , press unit, instrument display

MODULE

centimeter 2 , press m 2 /1, the instrument displays MODULE

m 2 , press Enter, instrument displays

area

0.0m 2 , press f 4 , the instrument displays SHOW

■, press ft 2 /2, the instrument displays SHOW 02■,

Press Enter, the instrument displays S:

×.×m 2 . At this point, the data stored in feet 2 /2 In the storage unit, the unit

Convert the data from square centimeters to square meters and display the result.

VI. Instructions for Use

1. Calculate the average measurement

For example: Measure the scale on the drawing as 1:10, unit is m 2 the area of the figure. (As shown in Figure 3.)

(1) Preparations before measurement

Determine on the contour line of the measured graphic Point a, which is the approximate center of the figure; taking a as the starting point, the instrument...

Arrange the apparatus as shown in Figure 3, so that the red dot on the tracer aligns with Point a coincides.

(2) Measurement

Set the power switch to ON, the instrument displays “measur 0.■”; press “unit,” and the instrument displays “MODULE cm.” 2

Press m 2 /1, the instrument displays MODULE m 2 , press Enter, the instrument displays "area"

0.0m 2 , press scale,

Instrument display SCALE

1:-, press m 2 /1, cm 2 /0, the instrument displays SCALE

1:10, press Enter,

Instrument display area

0.0m 2 , press trace, the instrument displays TRACE

0.0m 2 , at this moment the instrument is set

Set the ratio to 1:10, measurement state in square meters, move the tracer so that the red dot on the tracer follows the…

The contour line for area measurement moves in a clockwise direction, continuously returning to the starting point. Stop at a, press Enter, instrument

Device display S:

X.Xm 2 , X.X square meters is the data information for the measured figure A. Press f 5 , the instrument displays

STOCK

■, press m 2 /1, the instrument displays STOCK 01■; press Enter, and the instrument displays

TRACE 0.0m 2 . X.X Data information is stored in m 2 /1 In the storage unit, the instrument is in measurement mode.

(3) When measuring this area again, check whether the red dot on the plotter coincides with the starting point a. After checking, press

Esc, the instrument displays ARCA.

0.0m 2 , press trace, the instrument displays TRACE

0.0m 2 , mobile tracing

The instrument completes the measurement and stores the measurement data in another storage unit.

(4) After completing multiple measurements, press the Esc key, and the instrument will display “area.”

0.0m 2 , press f 1 , the instrument displays

AVERAGE

X ■, press Enter, and the instrument displays S:

XX.Xm 2 , XX.X square meters is the result of multiple measurements.

quantity The average value calculated for area A.

2. Summation Measurement

For example: The measured ratio is 1:5, where B is the area of the figure in square meters. (As shown in Figure 4.)

(1) Measurement Preparation Work

As shown in Figure 4, first the width is greater than The 300 mm graphic B is divided into two parts, namely the test graphics B1 and B2.

The contour line is approximated to the center point to determine the starting point. b1 and b2: Place the instrument (as shown in Figure 3) at position b1 in Figure 4.

(2) Measurement

Press Esc, the instrument displays "area"

0.0 cm 2 , press unit, instrument displays MODULE

centimeter 2

Press m 2 /1, the instrument displays MODULE

m 2 , press Enter, the instrument displays "area"

0.0m 2 , press

scale, the instrument displays SCALE

1: -, press mi 2 /5, the instrument displays SCALE

1:5, compress

Enter, the instrument displays area 0.0 m 2 , press trace, the instrument displays TRACE

0.0m 2 , at this moment the instrument

The set ratio is 1:5, with the measurement unit in square meters. Move the tracer so that the instrument’s red dot follows

Follow the contour of the area being measured in a clockwise direction, continuing until you return to the starting point. Stop at b1, press Enter, and the instrument displays

Example S: X.Xm 2

X

.X square meters is the measured area of figure B1. Press f. 5 , the instrument displays STOCK ■,

Press m 2 /1, the instrument displays STOCK 01■; press Enter, and the instrument displays TRACE 0.0 m. 2 , X.X number

According to the information being stored in m 2 /1 In the storage unit, the instrument is in measurement mode.

(3) Place the instrument (as shown in Figure 3) at position b2 in Figure 4.

Press Esc, the instrument displays "area"

0.0m 2 , press trace, instrument displays TRACE 0.0m 2 , move

Use the dynamic tracer, continue measuring according to the previous method, and then save the measurement data. feet 2 /in storage unit 2

(4) After completing the two measurements, press the Esc key, and the instrument will display “area 0.0m”. 2 , press f 2 , the instrument displays

SUMMAT 1-8■, press Enter, and the instrument displays S: X.Xm. 2 , X.X square meters corresponds to plots B1 and B2.

Sum of areas B.

3. Other Notes:

(1) When measuring multiple areas with different scales and units, the scale and units must be reset each time.

(2) When data from multiple measurements are stored and subjected to summation or averaging, all the internally stored data are,

All calculations are performed after scaling according to the unit last set. The unit shall be the one last set.

Correct.

(3) To measure other areas without power loss, f must be used. 3 After clearing the memory information, perform the sum or average calculation.

Value computation.

VII. Instrument Power Supply Instructions:

When the instrument displays When the “LACK BATTERY” message appears, it indicates low voltage and the instrument cannot operate normally. Please use

The QCJ-2000 model is a dedicated power supply for charging. When operating indoors, measurement can be performed simultaneously with charging.

VIII. Precautions

● Do not store the instrument in high-temperature, humid environments.

● Handle the instrument with care to avoid severe impacts that could damage the sensor and other components.

● Restart the power supply or press the RESET button to initialize the instrument; the default input ratio is 1:1, and the unit is

in square centimeters, the memory is 0.

● When the instrument is stored for an extended period, charge the battery once every 60 days to prevent battery damage.

●When the instrument displays “S: OVER,” the measurement result has overflowed. Please enter an appropriate scale and unit, then remeasure.

IX. Instrument Packing List:

1. One QCJ-2000 digital integrator

2. Dedicated charger

One

3. One user manual

4. One certificate of qualification

Harbin Optical Instruments Factory Co., Ltd.

HARBIN OPTICAL INSTRUMENT FACTORY LTD

Address: Jingwei Third Road, Daoli District, Harbin City, Heilongjiang Province 32 Number

Marketing Department Phone: 0451-84286338

Online Marketing Hotline: 0451-84219301

Technical Service Hotline: 0451-84213973

E-mail hopt@hopt.cn

Website: www.hopt.cn