Instruction Manual for the DQY-1A Geological Compass

Release Date:

2021-06-22

Product Implementation Standard: Q/HGY06-2020

I. Uses

DQY-1A The primary uses of the geological compass include: :

1 Measure Occurrence : Including strike, trend, and dip

2 , Topographic Survey : Including orientation ( Immediate rendezvous and docking ) Measure slope angle Set the level

3 , Measure the vertical angle.

II. Main Performance

1 , magnetic needle obstruction Niger time ( Magnetic needle deflection 90° The duration of remaining in the original position ) for 30-60 seconds

2 , Reading error :

a The angular error between the readings before and after the magnetic needle rotates shall not exceed 0.5°

b The magnetic needle is in 0–180° 90-270° The error caused by eccentricity at the location shall not exceed 0.5°;

c The reading error of the protractor shall not exceed 0.5°

3 , Level Sensitivity :

a The long level is 15 minutes scholar 3'/2mm

b circle The spirit level is 30 minutes scholar 5′/2mm

4 , Instrument external dimensions Inch ( long x wide x High ) for 80×70×31( m m)

  1. The instrument weight shall not exceed 0.23kg
  • Principle and Structure
  1. Principle : This instrument utilizes a magnetic object. ( That is, the magnetic needle. ) Possessing the characteristic of indicating a specific direction relative to the magnetic meridian. Reading in conjunction with the scale ring The target phase can be determined. to in the direction of the magnetic meridian. Based on the two selected measurement points ( or known measurement points ) It can determine the position of another unknown target.

2 , Structure ( Refer to the structural schematic diagram. )

The instrument consists of an upper cover. 6 With the shell 13 Through the connecting hinge 8 Forms the main body of the instrument. The upper cover houses a reflecting mirror. 7 Can reflect the target in the mirror. Housing 13 It is equipped with a long front sight on the exterior. 1 Compatible with a small collimator 5 Aimable at the target. The housing contains a scale dial. 2 and magnetic needle 3 The target's direction can be read directly. position value, Bubble level 10 It can indicate the instrument’s horizontal position. Long spirit level 4 and indicator panel 11 Supply Measure Use to measure slope angle Can be on the steering wheel 12 Read the inclination angle directly from the scale. Switch 9 For the magnetic needle braking mechanism A magnetic declination adjustment shaft is provided on the bottom surface of the housing.

This instrument features a compact structure, small footprint, convenient portability, reliable accuracy, and stable performance.

Tilt the long-range sight so that it lies in the same plane as the box surface. Lift the cover to 45 degree And the sight notch is vertical. Parallel top cover Align the indicator "0" Then, align the line of sight through the aperture on the sighting tip and the elliptical hole in the reflector. That is the horizontal line.

( Three ) Measure the vertical angle of the object

Flip the top cover to the limit position. Press the side of the instrument tightly against the object. ( Such as drill rods ) Representative plane Then adjust the long bubble to be centered. The indicator reading at this time This is the object’s vertical angle.

V. Notes item

1 The magnetic needle, the jewel bearing, and the agate bearing are the instrument’s most critical components. Should be carefully protected. Keep it clean To avoid affecting the sensitivity of the magnetic needle. When not in use, The instrument should be securely closed. After the instrument is closed, Automatically pick up the magnetic needle by operating the switch and lever. Disengage the thimble from the agate bearing. To prevent damage to the page pin.

2 1. Do not disassemble any hinges lightly. To prevent loosening and subsequent impact on accuracy.

3 , Avoid exposing the instrument to high temperatures and direct sunlight as much as possible. To prevent air leakage and malfunction due to blisters.

4 The pivoting parts of the hinge should be regularly lubricated with watch oil to prevent dry friction and breakage.

5 The instrument should be placed in a well-ventilated, dry location, away from magnetic objects.

 

 

 

 

 